GH Industrial Co., Ltd.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsPortable Water Meter Tester

Best Handheld Electronic Waterproof Temperature PH tester Portable Water Meter Tester For Indoor Gardening

Certification
Good quality Digital Ballast for sales
Good quality Digital Ballast for sales
I'm Online Chat Now

Best Handheld Electronic Waterproof Temperature PH tester Portable Water Meter Tester For Indoor Gardening

China Best Handheld Electronic Waterproof Temperature PH tester Portable Water Meter Tester For Indoor Gardening supplier

Large Image :  Best Handheld Electronic Waterproof Temperature PH tester Portable Water Meter Tester For Indoor Gardening

Product Details:

Place of Origin: China
Brand Name: PH meter
Certification: CE, RoHS
Model Number: PH meter

Payment & Shipping Terms:

Minimum Order Quantity: 50pcs
Price: negotiation
Packaging Details: Carton box
Delivery Time: 10-15 days
Payment Terms: TT/LC
Supply Ability: 20000PCS/month
Contact Now
Detailed Product Description
High Light:

multiparameter water quality meter

,

water tds meter

 

 

 

Best Handheld Electronic Waterproof Temperature PH tester Portable Water Meter Tester For Indoor Gardening

 

Quick Detail :

 

Name

PH tester

Brand Name

OEM offered

Measure Range

0.00-14.00ph

0.1℃-80℃

Accuracy

± 0.01ph

±0.5℃

Battery

3*1.5V(AG-13 button cell)

Weight

80g

Shape

Small rectangle

Certificate

CE, RoHS

 

What is PH tester ?

 

PH tester is an electronic device used for measuring the PH (acidity or alkalinity) of a liquid (though special probes are sometimes used to measure the pH of semi-solid substances). A typical pH meter consists of a special measuring probe (A glass electrode) connected to an electronic meter that measures and displays the pH reading, and this tester also can test temperature.

 

Applications : 

 

PH meter is an easy tool for testing the level of water quality, popular in water deal industry, household, travelling, and etc, especially hydroponics, greenhouse, horticulture and gardening.

 

Specifications

 

Model

PH tester

PH range

0.00~14.00 ph

Temp. range

0.1℃-80℃

PH Resolution

0.01ph

Temp. Resolution

0.1℃

PH Accuracy

± 0.01ph

Temp. Accuracy

±0.5℃

Auto. Temp. compensation

0.1℃-80℃

Power supply

3*1.5V(AG-13 button cell)

Operating Temp.

0℃-80℃

Calibration

Automatic two points calibration

Auto shut off function

4 minutes

Dimension

183mm*37*37mm

Weight

80kg

 

Operation 

 

1. Remove the protective sleeve

2. Clean the Electrode with distilled water and wipe clean the spare water.

3. Press the "ON/OFF" button .Turn on the meter.

4. Immerse the PH meter electrode in the solution 

5. Lightly shake the meter, read the data when the numeric stabilized.

6. The temperate displays at the bottom of the screen.

7. Press the "ON/OFF" button to shut off the instrument.

8. Clean the electrode with pure water, cover the electrode protective sleeve.

 

Calibration

 

1. Turn on the PH meter

2. Immerse the electrode in PH 6.86 standard buffer solution. (Under the temperature of 25°C)

3. After digital stabilized, press the "shift" button for 5 seconds, (The instrument comes into the automatic calibration Status).Wait until the display digital is 6.86pH Then complete PH 6.86 point calibration

4. Clean the electrode with distilled water and dry it with filter paper.  Immerse the electrode in pH 4.00 standard buffer solution

5. After digital stabilized, press "shift" button for 5 seconds. Wait until the digital is 4.00 pH Complete the ph 4.00 point calibration.

6. Clean the electrode with distilled water and wipe clean the spare water.Put the electrode in the PH 9.18 standard solution until the data stable,the data will be in 9.17pH----9.19pH. The data is in the range of allowable error.

7. This instrument calibration work is completed after all the steps.

 

Attention :

 

The instrument need recalibrate in the following condition.

1. Long time no use or use very long time after calibration

2. The electrode is used Very frequently.

3. The testing accuracy requirement is very high.

4. Do not press the "shift" button long time in the air.Otherwise the meter need recalibrate.

 

Low Batt

 

When the display value is fuzzy or unshown,it shall check the battery voltage. Lessing than 4.5V, it shall promptly replace the battery. When changing battery,unscrew battery cover and replace the battery. Pay attention to the polarity of battery.

 

Warranty  

 

The instrument maintains for a year, from the delivery date, guaranteeing due to production and material defects 

If the instrument need to be changed or repaired (not the artificial damage or caused by fault using), please mail the manual and the instrument together to our factory. We will solve all the problem for you .

 

Best Service :

 

1. All inquiry will get our prompt reply

2. Persist ant notice of production and shipment process

3. Customized logo printing and package are available here

4. Strict quality control and inspection before shipment

5. Normally ship out the order within 7-12days after order confirmation

 

 

Contact Details
GH Industrial Co., Ltd.

Fax: 86-21-55669991

Send your inquiry directly to us (0 / 3000)